2,644 research outputs found

    Search for high-mass Standard Model Higgs at the Tevatron

    Get PDF
    In this paper, we present results on searches for Standard Model Higgs boson production in the channels H → WW → l�+l�−, WH → WWW → l±l�±, and H → γγ. No evidence for the Higgs boson is observed, and we set upper bounds on Higgs boson production. Taking into account Standard Model predictions for Higgs boson production and decay, the existence of the Standard Model Higgs boson is excluded at 95% CL for mH = 170GeV

    Using a multi-level tailored design process to develop a customer satisfaction survey for university evaluation

    Get PDF
    A multi-level procedure is described in order to develop a total quality management survey tool in the field of engineering academia. As a first step a review of available evaluation tools for universities is conducted, resulting in over 150 items used for evaluation purposes. Secondly all dimensions of educational evaluation used in previous research are summarized, resulting in 15 dimensions. In a third step, items are assigned to the dimensions, overlapping items were combined or removed, and item content and dimensions were adjusted to the specific conditions of the target faculty. Fourthly, the resulting twelve dimensions were used in first, investigative interviews in the target population. Results indicate that eleven dimensions sufficiently mapped all aspects of evaluation. After revising the items to improve understanding in a fifth step cognitive pretests were conducted. The final revision resulted in 83 items assigned to eleven dimensions

    Empirical competence-testing: A psychometric examination of the German version of the Emotional Competence Inventory

    Get PDF
    The “Emotional Competence Inventory“ (ECI 2.0) by Goleman and Boyatzis assesses emotional intelligence (EI) in organizational context by means of 72 items in 4 clusters (self-awareness, self- management, social awareness, social skills) which at large consist of 18 competencies. Our study examines the psychometric properties of the first German translation of this instrument in two different surveys (N = 236). If all items are included in reliability analysis the ECI is reliable (Cronbach’s Alpha = .90), whereas the reliability of the four sub dimensions is much smaller (Alpha = .62 - .81). For 43 items the corrected item-total correlation with its own scale is higher than correlations with the other three clusters. Convergent validity was examined by using another EI instrument (Wong & Law, 2002). We found a significant correlation between the two instruments (r = .41). The German version of the ECI seems to be quite useful, although the high reliability is achieved by a large number of items. Possibilities of improvement are discussed

    Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter-Defibrillators in the Cardiovascular Research Network

    Get PDF
    BACKGROUND: Primary prevention implantable cardioverter-defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems. METHODS AND RESULTS: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; nonischemic cardiomyopathy \u3c 9 months\u27 duration; and New York Heart Association class IV heart failure with cardiac resynchronization therapy defibrillator. Among 2540 patients, 35% were \u3c 65 years old, 26% were women, and 59% were white. During 27 (median) months, 738 (29%) received \u3e /=1 therapy. Three-year therapy risk was 36% (appropriate, 24%; inappropriate, 12%). Appropriate therapy was more common in men (adjusted hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.43-2.35). Inappropriate therapy was more common in patients with atrial fibrillation (adjusted HR, 2.20; 95% CI, 1.68-2.87), but less common among patients \u3e /=65 years old versus younger (adjusted HR, 0.72; 95% CI, 0.54-0.95) and in recent implants (eg, in 2009 versus 2006; adjusted HR, 0.66; 95% CI, 0.46-0.95). In Centers for Medicare and Medicaid Services Coverage With Evidence Development analysis, inappropriate therapy was less common with cardiac resynchronization therapy defibrillator versus single chamber (adjusted HR, 0.55; 95% CI, 0.36-0.84); therapy risk did not otherwise differ for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups. CONCLUSIONS: In this community cohort of primary prevention patients receiving ICD, therapy delivery varied across demographic and clinical characteristics, but did not differ meaningfully for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups

    Does Perceptual Learning Suffer from Retrograde Interference?

    Get PDF
    In motor learning, training a task B can disrupt improvements of performance of a previously learned task A, indicating that learning needs consolidation. An influential study suggested that this is the case also for visual perceptual learning [1]. Using the same paradigm, we failed to reproduce these results. Further experiments with bisection stimuli also showed no retrograde disruption from task B on task A. Hence, for the tasks tested here, perceptual learning does not suffer from retrograde interference

    Emotional Intelligence and its consequences for occupational and life satisfaction - Emotional Intelligence in the context of irrational beliefs

    Get PDF
    According to Albert Ellis' theory of Rational Emotive Behavior Therapy irrational beliefs (IB) lead to maladaptive emotions. A central component of irrationality is the denial of one's own possibilities to control important aspects of life. A specific IB is that one cannot control and thus cannot avoid certain emotion states. Emotion research considers regulative emotion control a pivotal component of the concept of emotional intelligence (EI). A negative association between IB and EI can thus be theoretically derived from both concepts. Furthermore both should be related to life satisfaction. We examined the relationship between IB and EI using standardized questionnaire instruments and the predictive value of both concepts regarding life satisfaction. We found a significant negative correlation between both conceptions (r = -.21). Life satisfaction and occupational satisfaction are better predicted by IB. R² increases from .04 to .12 when both concepts are incorporated in regression analysis

    MR-Eyetracker: a new method for eye movement recording in functional magnetic resonance imaging

    Get PDF
    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2° at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI
    • …
    corecore